LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2017 >> RAV4 XLE, AWD >> Repair and Diagnosis >> Engine Mechanical >> Auxiliary Emission Control Systems >> Emission Control System (2AR-FE) (Service Information) (Except Hybrid) >> PCV Valve >> Installation [12/2012 - ] >> Procedure

Installation [12/2012 - ]: Procedure

  1. INSTALL PCV VALVE 
    1. Apply adhesive to 2 or 3 threads of the PCV valve.

      Adhesive

      Toyota Genuine Adhesive 1324, Three Bond 1324 or equivalent

    2. Using a 19 mm deep socket wrench, install the PCV valve.

      Torque: 27 N*m (275 kgf*cm, 20 ft.*lbf) 

    3. Connect the No. 2 PCV hose to the PCV valve, and slide the clamp to secure it.
  2. INSTALL INTAKE MANIFOLD 

    Refer to INSTALLATION [12/2012 - 10/2015] , or refer to INSTALLATION [10/2015 - ]