On-Vehicle Inspection [12/2012 - ]: Procedure
- INSPECT AUTOMATIC LIGHT CONTROL SENSOR
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition 6 (CLTB) - 3 (CLTE) Ignition switch on (IG) 11 to 14 V *a Component with harness connected
(Automatic Light Control Sensor) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 3 (CLTE) - Body ground Always Below 1 Ω - Reconnect the automatic light control sensor connector.
- Check the waveform of the automatic light control sensor connector.
Waveform
Tester Connection Tool Setting Switch Condition Specified Condition 3 (CLTE) - 5 (CLTS) 5 V/DIV., 5 msec./DIV. Ignition switch on (IG), headlight dimmer switch on AUTO Correct waveform is as shown HINT:
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, there may be a malfunction in the automatic light control sensor.
- Measure the voltage according to the value(s) in the table below.