Hazard Warning Switch Circuit [12/2012 - ]: Procedure
- READ VALUE USING TECHSTREAM (HAZARD WARNING SIGNAL SWITCH)
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [12/2012 - ] .
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch signal ON or OFF ON: Hazard warning signal switch on
OFF: Hazard warning signal switch off- Body Electrical > Combination Meter > Data List
Tester Display Hazard Flasher Switch OK
The display is as specified in the normal condition column.
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE:
Refer to PROBLEM SYMPTOMS TABLE [12/2012 - 10/2015] or PROBLEM SYMPTOMS TABLE [10/2015 - ] .
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)
- Remove the telltale light assembly (hazard warning signal switch).
Refer to REMOVAL [12/2012 - ] .
- Inspect the telltale light assembly (hazard warning signal switch).
Refer to INSPECTION [12/2012 - ] .
Result:
NG
REPLACE TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH). Refer to REMOVAL [12/2012 - ] .
Result:
OK
See step 3
- Remove the telltale light assembly (hazard warning signal switch).
- CHECK HARNESS AND CONNECTOR (TELLTALE LIGHT ASSEMBLY [HAZARD WARNING SIGNAL SWITCH] - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the G43 telltale light assembly (hazard warning signal switch) connector.
- Disconnect the G17 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G17-3 (HAZ) - G43-7 (TB) Always Below 1 Ω G43-13 (E) - Body ground Always Below 1 Ω G17-3 (HAZ) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2012 - ] .
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR