Inspection Procedure
HINT:
- If the auxiliary battery voltage is applied to terminal +B1 or +B2 of the power management control ECU, even though the power switch is off, the circuit is shorted to +B.
- After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
- Turn the power switch on (IG) and wait for 15 seconds or more.
- Turn the power switch off and wait for 30 seconds or more.