Pattern Select Switch Eco Mode Circuit [08/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (CAN BUS CHECK) Refer to 2
B → Refer to 11
A: Go to next step
- CHECK DTC OUTPUT (HEALTH CHECK) Refer to 3
B → GO TO DTC CHART
A: Go to next step
- PERFORM ACTIVE TEST USING TECHSTREAM (INDICAT. ECO MODE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Body Electrical / Combination Meter / Active Test / Indicat. ECO Mode.
- Perform the "Indicat. ECO MODE" Active Test.
OK
The ECO MODE indicator lamp comes on or blinks.
Result
Result Proceed to OK A NG (w/o Multi-information Display) B NG (w/ Multi-information Display) C - Turn the power switch off.
B → Refer to 12
C → Refer to 14
A: Go to next step
- READ VALUE USING TECHSTREAM (ECO MODE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Data List / ECO Mode.
- Read the value displayed on the Techstream.
Tester Display Measurement Item/Range Normal Condition ECO Mode ECO mode transition availability/
ON or OFFIn ECO mode: ON Result
Result Proceed to The Techstream display changes according to the ECO switch operation. A The Techstream display does not changes according to the ECO switch operation. B
B → Refer to 5
A → Refer to 10
- READ VALUE USING TECHSTREAM (ECO SWITCH)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Body Electrical / Air Conditioning / Data List / ECO Switch.
- Read the value displayed on the Techstream.
Tester Display Measurement Item/Range Normal Condition ECO Switch ECO switch condition/
ON or OFFECO switch being pushed and held: ON
ECO switch not pushed: OFFResult
Result Proceed to The Techstream display changes according to the ECO switch operation. A The Techstream display does not changes according to the ECO switch operation. B
B → Refer to 6
A → Refer to 13
- CHECK COMBINATION SWITCH ASSEMBLY (ECO SWITCH)
- Remove the combination switch assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition L155-5 (ECU) - L155-3 (E) ECO switch being pushed and held Below 1 Ω ECO switch not pushed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Combination Switch Assembly) - Install the combination switch assembly.
NG → Refer to 9
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - BODY GROUND) Refer to 7
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COMBINATION SWITCH)
- Disconnect connector L17 from the air conditioning amplifier assembly.
- Disconnect connector L155 from the combination switch assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L17-15 (ECOS) - L155-5 (ECU) Always Below 1 Ω L17-15 (ECOS) or L155-5 (ECU) - Body ground Always 10 kΩ or higher TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)*b Front view of wire harness connector
(to Combination Switch Assembly) - Connect the combination switch assembly connector.
- Connect the air conditioning amplifier assembly connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → Refer to 13
- REPLACE COMBINATION SWITCH ASSEMBLY. Refer to COMPONENTS [08/2015 - ]
- CHECK FOR INTERMITTENT PROBLEMS. Refer to CHECK FOR INTERMITTENT PROBLEMS [08/2015 - ]
- GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ]
- REPLACE METER CIRCUIT PLATE. Refer to COMPONENTS [08/2015 - ]
- REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to COMPONENTS [08/2015 - ]
- REPLACE COMBINATION METER SUB-ASSEMBLY. Refer to COMPONENTS [08/2015 - ]