Installation [11/2015 - ]: Procedure
- INSTALL LOWER NO. 1 INSTRUMENT PANEL AIRBAG ASSEMBLY
- Check that the power switch is off.
- Check that the cable is disconnected from the negative (-) auxiliary battery terminal.
- Connect the airbag connector to the lower No. 1 instrument panel airbag assembly.
*a Airbag Connector *b Airbag Connector Lock NOTE:When connecting any airbag connector, take care not to damage the airbag wire harness.
- Push in the airbag connector lock to install the airbag connector.
- Engage the 4 claws and hook to temporarily install the lower No. 1 instrument panel airbag assembly.
- Install the lower No. 1 instrument panel airbag assembly with the 2 bolts.
Torque: 10 N.m (102 kgf.cm, 7 ft./lbf)
NOTE:Confirm that the lower No. 1 instrument panel airbag assembly is installed securely without any excessive gaps and is not protruding outward.
- INSTALL LOWER INSTRUMENT PANEL FINISH PANEL ASSEMBLY
Refer to PROCEDURE - Step 20 [11/2015 - 11/2017] , or refer to PROCEDURE - Step 22 [11/2017 - 08/2019] , or refer to PROCEDURE - Step 21 [08/2019 - ]
- CONNECT HOOD LOCK CONTROL LEVER SUB-ASSEMBLY
Refer to PROCEDURE - Step 21 [11/2015 - 11/2017] , or refer to PROCEDURE - Step 23 [11/2017 - 08/2019] , or refer to PROCEDURE - Step 22 [08/2019 - ]
- INSTALL NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY
Refer to PROCEDURE - Step 22 [11/2015 - 11/2017] , or refer to PROCEDURE - Step 24 [11/2017 - 08/2019] , or refer to PROCEDURE - Step 23 [08/2019 - ]
- INSTALL COWL SIDE TRIM BOARD LH
Refer to PROCEDURE - Step 50 [11/2015 - 12/2018] , or refer to PROCEDURE - Step 46 [12/2018 - 07/2020] , or refer to PROCEDURE - Step 46 [07/2020 - ]
- INSTALL FRONT DOOR SCUFF PLATE LH
Refer to PROCEDURE - Step 51 [11/2015 - 12/2018] , or refer to PROCEDURE - Step 47 [12/2018 - 07/2020] , or refer to PROCEDURE - Step 47 [07/2020 - ]
- INSTALL INSTRUMENT CLUSTER FINISH PANEL GARNISH ASSEMBLY
Refer to PROCEDURE - Step 25 [11/2015 - 11/2017] , or refer to PROCEDURE - Step 27 [11/2017 - 08/2019] , or refer to PROCEDURE - Step 26 [08/2019 - ]
- INSTALL INSTRUMENT PANEL FINISH PANEL END LH
Refer to PROCEDURE - Step 26 [11/2015 - 11/2017] , or refer to PROCEDURE - Step 28 [11/2017 - 08/2019] , or refer to PROCEDURE - Step 27 [08/2019 - ]
- CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Refer to INITIALIZATION [11/2015 - 11/2017] , or refer to INITIALIZATION [11/2017 - 12/2018] , or refer to INITIALIZATION [12/2018 - 08/2019] , or refer to INITIALIZATION [08/2019 - 07/2020] , or refer to INITIALIZATION [07/2020 - ]
- PERFORM DIAGNOSTIC SYSTEM CHECK
Refer to DTC CHECK / CLEAR [11/2015 - 12/2018] , or refer to DTC CHECK / CLEAR [12/2018 - 08/2019] , or refer to DTC CHECK / CLEAR [08/2019 - ]
- INSPECT SRS WARNING LIGHT
Refer to DIAGNOSIS SYSTEM [11/2015 - 08/2016] , or refer to DIAGNOSIS SYSTEM [08/2016 - 08/2019] , or refer to OPERATION CHECK [08/2019 - 07/2020] , or refer to OPERATION CHECK [07/2020 - ]