Front Fog Light Circuit [12/2018 -]: Procedure
- CHECK OPERATION (TAILLIGHTS)
Result:
NG
GO TO PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2018 -]
Result:
OK
See step 2
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Fog Light Relay Front fog lights OFF or ON Light control switch in tail position Body Electrical > Main Body > Active Test
Tester Display Front Fog Light Relay OK
Front fog light relay operates. (Front fog lights come on.)
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2018 -]
Result:
NG
See step 3
- CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - FOG FR RELAY)
- Remove the FOG FR relay.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 5 (FOG FR relay) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY INPUT VOLTAGE)
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 2 (FOG FR relay) - Body ground Power switch off, Taillights on 11 to 14 V Result
Proceed to OK NG
Result:
NG
See step 9
Result:
OK
See step 5
- Measure the voltage according to the value(s) in the table below.
- INSPECT FOG FR RELAY
- Inspect the FOG FR relay.
Refer to ON-VEHICLE INSPECTION [11/2015 -]
Result
Proceed to OK NG
Result:
NG
REPLACE FOG FR RELAY
Result:
OK
See step 6
- Inspect the FOG FR relay.
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - FOG LIGHT ASSEMBLY)
- Disconnect the W5 fog light assembly LH connector.
- Disconnect the W4 fog light assembly RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
& Routing (W5, W4)
(W5)
(W4)
Tester Connection Condition Specified Condition 3 (FOG FR relay) - W5-1 (B) Always Below 1 Ω 3 (FOG FR relay) - W4-1 (B) Always Below 1 Ω 3 (FOG FR relay) or W5-1 (B) - Body ground Always 10 kΩ or higher 3 (FOG FR relay) or W4-1 (B) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 7
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 3A instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (FOG FR relay) - 3A-52 Always Below 1 Ω 1 (FOG FR relay) or 3A-52 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 8
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Refer to REMOVAL [12/2018 - 07/2020] , or refer to REMOVAL [07/2020 -]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3A-52 - MB-7 (FFGO) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2018 - 07/2020] , or refer to REMOVAL [07/2020 -]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2018 - 07/2020] , or refer to REMOVAL [07/2020 -]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 3D instrument panel junction block assembly connector.
- Measure the resistance according to the value(s)in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (FOG FR relay) - 3D-11 Always Below 1 Ω 2 (FOG FR relay) or 3D-11 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2018 - 07/2020] , or refer to REMOVAL [07/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR