Installation [09/2016 - 05/2019]: Procedure
- INSTALL AUXILIARY BATTERY
- w/ Battery Insulator:
- Install the battery insulator to the auxiliary battery.
- Install the auxiliary battery.
- Set the battery clamp sub-assembly as shown in the illustration.
- Install the bolt.
Torque: 15.4 N*m (157 kgf*cm, 11 ft.*lbf)
- Connect the cable to the positive (+) auxiliary battery terminal and tighten the nut.
Torque: 5.6 N*m (57 kgf*cm, 50 in.*lbf)
- Engage the 2 claws to close the battery terminal cap.
- w/ Battery Insulator:
- CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
- Connect the cable to the negative (-) auxiliary battery terminal and tighten the nut.
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
NOTE:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Refer to INITIALIZATION [09/2016 - 05/2019]
- Connect the cable to the negative (-) auxiliary battery terminal and tighten the nut.