Inspection [09/2016 - ]: Procedure
- INSPECT LIGHT CONTROL RHEOSTAT (COMBINATION SWITCH ASSEMBLY)
*a Component without harness connected
(Light Control Rheostat Switch (Combination Switch Assembly))- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 8 (RV) - 6 (E) Light control rheostat up switch pressed Below 1 Ω Light control rheostat up switch not pressed 10 kΩ or higher 8 (RV) - 6 (E) Light control rheostat down switch pressed 1.71 to 1.89 kΩ Light control rheostat down switch not pressed 10 kΩ or higher If the result is not as specified, replace the light control rheostat switch (combination switch assembly).
- Illumination Inspection
*a Component without harness connected
(Light Control Rheostat Switch (Combination Switch Assembly))- Apply auxiliary battery voltage to the light control rheostat switch (combination switch assembly) and check that it illuminates.
OK
Condition Specified Condition Auxiliary battery positive (+) → Terminal 10 (ILL+)
Auxiliary battery negative (-) → Terminal 1 (ILL-)Illuminates If the result is not as specified, replace the light control rheostat switch (combination switch assembly).
- Apply auxiliary battery voltage to the light control rheostat switch (combination switch assembly) and check that it illuminates.
- Measure the resistance according to the value(s) in the table below.