Automatic High Beam Switch Circuit [09/2016 - 07/2020]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Auto High Beam Main Switch Automatic high beam main switch (No. 2 combination switch assembly) signal OFF or ON OFF: Automatic high beam main switch (No. 2 combination switch assembly) not pressed
ON: Automatic high beam main switch (No. 2 combination switch assembly) pressed- Body Electrical > Main Body > Data List
Tester Display Auto High Beam Main Switch OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [09/2016 - 07/2020]
Result:
NG
See step 2
- INSPECT AUTOMATIC HIGH BEAM MAIN SWITCH (NO. 2 COMBINATION SWITCH ASSEMBLY)
- Remove the automatic high beam main switch (No. 2 combination switch assembly).
Refer to REMOVAL [09/2016 - ]
- Inspect the automatic high beam main switch (No. 2 combination switch assembly).
Refer to INSPECTION [09/2016 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE AUTOMATIC HIGH BEAM MAIN SWITCH (NO. 2 COMBINATION SWITCH ASSEMBLY). Refer to REMOVAL [09/2016 - ]
Result:
OK
See step 3
- Remove the automatic high beam main switch (No. 2 combination switch assembly).
- CHECK HARNESS AND CONNECTOR (AUTOMATIC HIGH BEAM MAIN SWITCH (NO. 2 COMBINATION SWITCH ASSEMBLY) - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND BODY GROUND)
- Disconnect the I18 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I52-9 (+B) - I18-17 (AHBI) Always Below 1 Ω I52-9 (+B) or I18-17 (AHBI) - Body ground Always 10 kΩ or higher I52-8 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [09/2016 - 07/2020]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR