Operating Light Control Rheostat does not Change Light Brightness [11/2015 - ]: Procedure
- SYSTEM CHECK
- Confirm the symptoms.
Result
Result Proceed to Meter illumination does not change when operating the light control rheostat. A Dimmer function cannot be canceled. B
Result:
B
See step 5
Result:
A
See step 2
- Confirm the symptoms.
- READ VALUE USING TECHSTREAM (RHEOSTAT VALUE)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Rheostat value Light control rheostat/Min.: 0 (dark), Max.: 100 (bright) Light control rheostat value 0 (dark) The value changes with rheostat operation Light control rheostat value 100 (bright) OK
The value displayed on the Techstream gradually changes with actual rheostat knob operation.
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [11/2015 - ] )
Result:
NG
See step 3
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat (Refer to REMOVAL [11/2015 - ]
).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 6 (E) - 7 (TR) Light control rheostat is fully turned downwards (MIN.) Below 50 Ω Light control rheostat position is between MIN. and MAX. The value changes gradually (Between 0 to 12 kΩ) Light control rheostat is fully turned upwards (MAX.) 8 to 12 kΩ TEXT IN ILLUSTRATION*a Component without harness connected
(Light Control Rheostat)
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT
Refer to REMOVAL [11/2015 - ] )
Result:
OK
See step 4
- Remove the light control rheostat (Refer to REMOVAL [11/2015 - ]
).
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the G1 combination meter assembly connector.
- Disconnect the G29 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G1-17 (SW2) - G29-7 (TR) Always Below 1 Ω G1-17 (SW2) - Body ground Always 10 kΩ or higher G1-19 (SW3) - G29-6 (E) Always Below 1 Ω G1-19 (SW3) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [11/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW Tail cancel switch/OFF or ON OFF: Tail cancel switch off Dimming of dash lights is possible ON: Tail cancel switch on Dimming of dash lights is canceled HINT:
The tail cancel switch is operated by turning the light control rheostat knob fully upward.
OK
Condition displayed on the Techstream is the same as the actual light control rheostat knob position.
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [11/2015 - ] )
Result:
NG
See step 6
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat (Refer to REMOVAL [11/2015 - ]
).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 8 (TC) - 9 (T) Light control rheostat position is not fully turned upwards (Tail cancel switch is off) Below 50 Ω Light control rheostat is fully turned upwards (Tail cancel switch is on) 8 to 12 kΩ TEXT IN ILLUSTRATION*a Component without harness connected
(Light Control Rheostat)
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT
Refer to REMOVAL [11/2015 - ] )
Result:
OK
See step 7
- Remove the light control rheostat (Refer to REMOVAL [11/2015 - ]
).
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the G1 combination meter assembly connector.
- Disconnect the G29 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G1-18 (SW1) - G29-9 (T) Always Below 1 Ω G1-18 (SW1) - Body ground Always 10 kΩ or higher G1-16 (TC) - G29-8 (TC) Always Below 1 Ω G1-16 (TC) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [11/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR