Entire Combination Meter does not Operate [11/2015 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the G1 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G1-20 (ET) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition G1-21 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON (IG) 11 to 14 V G1-1 (B) - Body ground Ignition switch off 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [11/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the G1 combination meter assembly connector.