Inspection [11/2015 - ]: Procedure
- INSPECT LIGHT CONTROL RHEOSTAT
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 6 (E) - 7 (TR) Light control rheostat is fully turned downwards (MIN.) Below 50 Ω 6 (E) - 7 (TR) Light control rheostat position is between MIN. and MAX. The value changes gradually (Between 0 to 12 kΩ 6 (E) - 7 (TR) Light control rheostat is fully turned upwards (MAX.) 8 to 12 kΩ 8 (TC) - 9 (T) Light control rheostat position is not fully turned upwards (Tail cancel switch is off) Below 50 Ω 8 (TC) - 9 (T) Light control rheostat is fully turned upwards (Tail cancel switch is on) 8 to 12 kΩ TEXT IN ILLUSTRATION*a Component without harness connected
(Light Control Rheostat)If the value is not as specified, replace the light control rheostat.
- Measure the resistance according to the value(s) in the table below.