SRS Warning Light does not Come ON [06/2015 - ]: Procedure
- CHECK AUXILIARY BATTERY
- Measure the auxiliary battery voltage.
Standard voltage
11 to 14 V (IG OFF)
HINT:
- It may be possible to tell whether the auxiliary battery is discharged by operating the horn.
- If the voltage is below 11 V, recharge or replace the auxiliary battery before proceeding to the next step.
Result
Proceed to OK NG
Result:
NG
REPLACE OR RECHARGE AUXILIARY BATTERY
Result:
OK
See step 2
- Measure the auxiliary battery voltage.
- CHECK CONNECTION OF CONNECTOR
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
- Check that the connector is properly connected to the combination meter assembly.
Result
Result Proceed to The connector is properly connected A The connector is not properly connected B
Result:
B
CONNECT CONNECTOR PROPERLY
Result:
A
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - AUXILIARY BATTERY AND BODY GROUND)
- Disconnect the connector from the combination meter assembly.
*a Front view of wire harness connector
(to Combination Meter Assembly) - Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition G13-21 (IG+) - Body ground Power switch on (IG) 11 to 14 V G13-22 (B) - Body ground Power switch off 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G13-28 (ES) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- Disconnect the connector from the combination meter assembly.
- CHECK SRS WARNING LIGHT (SHORT TO GROUND)
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
- Connect the connector to the combination meter assembly.
- Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
- Turn the power switch on (IG).
- Check the SRS warning light condition.
OK
After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.
HINT:
The primary check period is approximately 6 seconds after the power switch is turned on (IG).
Result
Proceed to OK NG
Result:
OK
REPLACE AIRBAG SENSOR ASSEMBLY. Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2015 - ]