Meter Illumination does not Dim at Night [08/2015 - ]: Procedure
- CHECK FOR DTC
- Check for DTCs (Refer to DTC CHECK / CLEAR [08/2015 - ]
).RESULT
Result Proceed to CAN communication system DTC is not output A CAN communication system DTC is output B
Result:
NG
GO TO DTC B1244
Result:
OK
See step 2
- Check for DTCs (Refer to DTC CHECK / CLEAR [08/2015 - ]
).
- PERFORM ACTIVE TEST USING TECHSTREAM
- Operate the Techstream according to the display and select Data List (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW* TAIL cancel switch condition/ON or OFF ON: TAIL cancel switch ON
OFF: TAIL cancel switch OFF- Rheostat value Light control rheostat switch input/Min.: 0, Max.: 100 Light control rheostat switch is fully turned right (0) → fully turned left (100) Unit: % HINT:
*: w/ TAIL Cancel Switch
OK
Light brightness can be changed within specified range by manual operation.
Result:
OK
CHECK CUSTOMIZE SETTING
(Refer to CUSTOMIZE PARAMETERS [08/2015 - ] )
Result:
NG
See step 3
- Operate the Techstream according to the display and select Data List (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).
- REPLACE COMBINATION METER ASSEMBLY
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
(Refer to REMOVAL [08/2015 - ] )
Result:
NG
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
(Refer to REMOVAL [08/2015 - ] )