Removal [11/2016 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
See step 1
- REMOVE SERVICE PLUG GRIP
Refer to REMOVAL [02/2014 - ]
- REMOVE RADIATOR ASSEMBLY
Refer to REMOVAL [11/2016 - ]
- CHECK TERMINAL VOLTAGE
- Remove the inverter terminal cover.
Refer to PROCEDURE - Step 9
- Check the terminal voltage.
Refer to PROCEDURE - Step 10
- Install the inverter terminal cover.
Refer to PROCEDURE - Step 18
- Remove the inverter terminal cover.
- DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
- DISCONNECT SUCTION HOSE SUB-ASSEMBLY
- REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
- Using a screwdriver, slide the green-colored lock of the connector as shown in the illustration to release it and disconnect the connector.
*a Green-colored Lock WARNING:Make sure to wear insulating gloves.
NOTE:Insulate the disconnected terminals and connector with insulating tape.
- Disconnect the connector.
- Remove the bolt.
- Disengage each clamp.
- for Type A:
- for Type B:
- Using a screwdriver, slide the green-colored lock of the connector as shown in the illustration to release it and disconnect the connector.