Entire Combination Meter does not Operate [12/2013 - 11/2016]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BODY GROUND)
- Disconnect the F22 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F22-11 (E2) - Body ground Always Below 1 Ω F22-20 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F22-13 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V F22-1 (B) - Body ground Always 11 to 14 V
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2013 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR