DTC B1500: Fuel Sender Open Detected [12/2013 - 11/2016]: Procedure
- READ VALUE USING TECHSTREAM (FUEL INPUT)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Fuel Input Fuel input Min.: 0 L, Max.: 172.5 L Fuel receiver gauge indicates F: 64.8 L
Fuel receiver gauge indicates 3/4: 51.6 L
Fuel receiver gauge indicates 1/2: 36.0 L
Fuel receiver gauge indicates 1/4: 20.4 L
Fuel receiver gauge indicates E: 7.2 LUnit: Liter Body Electrical > Combination Meter > Data List
Tester Display Fuel Input Result Proceed to Fuel level data can be displayed on the Techstream and DTC B1500 is output. A Fuel level data cannot be displayed on the Techstream. B
Result:
A
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2013 - ]
Result:
B
See step 2
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Disconnect the F22 combination meter assembly connector.
*a Front view of wire harness connector
(to Combination Meter Assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F22-14 (FR) - F22-15 (FE) Always 13.5 to 414.5 Ω
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2013 - ]
Result:
NG
See step 3
- Disconnect the F22 combination meter assembly connector.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY)
- Disconnect the F22 combination meter assembly connector.
- Disconnect the M9 fuel suction tube with pump and gauge assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F22-14 (FR) - M9-2 (FS) Always Below 1 Ω F22-15 (FE) - M9-3 (FE) Always Below 1 Ω F22-14 (FR) - Body ground Always 10 kΩ or higher F22-15 (FE) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly.
for 1AR-FE: Refer to REMOVAL [12/2013 - ]
for 2GR-FE: Refer to REMOVAL [12/2013 - 11/2016]
- Inspect the fuel sender gauge assembly.
for 1AR-FE: Refer to INSPECTION [12/2013 - ]
for 2GR-FE: Refer to INSPECTION [12/2013 - 11/2016]
OK
Fuel sender gauge assembly is normal.
Result:
NG
REPLACE FUEL SENDER GAUGE ASSEMBLY
for 1AR-FE: Refer to REMOVAL [12/2013 - ]
for 2GR-FE: Refer to REMOVAL [12/2013 - 11/2016]
Result:
OK
See step 5
- Remove the fuel sender gauge assembly.
- INSPECT FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A-2 (FS) - B-2 Always Below 1 Ω A-3 (FE) - B-1 Always Below 1 Ω *a Component without harness connected
(Fuel Suction Tube with Pump and Gauge Assembly)
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2013 - ]
Result:
NG
REPLACE FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY
for 1AR-FE: Refer to REMOVAL [12/2013 - ]
for 2GR-FE: Refer to REMOVAL [12/2013 - 11/2016]
- Measure the resistance according to the value(s) in the table below.