Ambient Light Circuit [12/2013 - ]: Procedure
- CONFIRM SYMPTOMS
- Confirm problem symptoms.
Result
Result Proceed to Ambient lights do not come on A Ambient light dimmer control does not operate B
Result: 2
B
See step 5
Result: 1
A
See step 2
- Confirm problem symptoms.
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Check that the ambient lights come on.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Interior Illumination Light1 Ambient lights ON or OFF Precondition for using the Active Test to turn lights on and off: - Ignition switch is turned off just before performing the Active Test.
Body Electrical > Main Body > Active Test
Tester Display Interior Illumination Light1 OK
All ambient lights come on.
Result
Result Proceed to OK A NG (All ambient lights do not illuminate) B NG (Ambient light does not illuminate (for Front Door)) C NG (Ambient light does not illuminate (for Rear Door)) NG (Ambient light does not illuminate (for Instrument Panel Side))
Result: 1
A
PROBLEM SYMPTOMS TABLE FOR EACH PROBLEM SYMPTOM. Refer to PROBLEM SYMPTOMS TABLE [12/2013 - ]
Result: 3
C
GO TO PROBLEM SYMPTOMS TABLE FOR EACH PROBLEM SYMPTOM. Refer to PROBLEM SYMPTOMS TABLE [12/2013 - ]
Result: 2
B
See step 3
- CHECK HARNESS AND CONNECTOR (POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 4L instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4L-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 4
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly.
Refer to REMOVAL [12/2013 - ]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Refer to REMOVAL [12/2013 - ]
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 4L-1 - 4H-22 Always Below 1 Ω 4L-1 - 4D-31 Always Below 1 Ω 4H-27 - MB-26 (LED1) Always Below 1 Ω 4D-9 - MB-26 (LED1) Always Below 1 Ω Result
Proceed to OK NG
Result: 1
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2013 - ]
Result: 2
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2013 - ]
- Remove the instrument panel junction block assembly.
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Check that the ambient lights come on.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Interior Illumination Light1 Ambient lights ON or OFF Preconditions for using the Active Test to check dimmer controlled illumination: - Engine running
- Shift lever is in any position other than P.
Body Electrical > Main Body > Active Test
Tester Display Interior Illumination Light1 OK
Ambient light dimmer control operates.
Result
Proceed to OK NG
Result: 1
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2013 - ]
Result: 2
NG
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2013 - ]