Inspection [12/2013 - ]: Procedure
- INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Air Conditioning Control Assembly (Hazard Warning Signal Switch))Standard Resistance
Tester Connection Condition Specified Condition 5 (GND) - 7 (HAZ) Hazard warning signal switch off 10 kΩ or higher Hazard warning signal switch on Below 1 Ω If the result is not as specified, replace the air conditioning control assembly.
- Illumination Inspection
- Apply battery voltage to the air conditioning control assembly and check that the switch illuminates.
OK
Condition Specified Condition Battery positive (+) → Terminal 3 (ILL+)
Battery negative (-) → Terminal 1 (ILL-)Illuminates If the result is not as specified, replace the air conditioning control assembly.
- Apply battery voltage to the air conditioning control assembly and check that the switch illuminates.
- Measure the resistance according to the value(s) in the table below.