Inspection [12/2013 - 11/2016]: Procedure
- INSPECT CLOCK ASSEMBLY
- Apply battery voltage to the clock assembly and check that the indicator light illuminates.
*a Security Indicator Light *b Component without harness connected
(Clock Assembly)OK
Battery Connection Specified Condition Battery positive (+) → Terminal 9
Battery negative (-) → Terminal 8Security indicator light comes on If the result is not as specified, replace the clock assembly.
- Apply battery voltage to the clock assembly and check that the indicator light illuminates.