Power Windows do not Operate Using All Window Switch [08/2015 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the K11 power window regulator master switch assembly connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition K11-3 (B) - Body ground Always 11 to 14 V K11-13 (PWS) - Body ground Ignition switch ON 11 to 14 V Standard Resistance
Tester Connection Condition Specified Condition K11-1 (GND) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
- Replace the power window regulator master switch assembly. Refer to REMOVAL [08/2015 - ] .
NEXT: Go to next step
- CHECK POWER WINDOW CONTROL SYSTEM
- Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door). Refer to OPERATION CHECK [08/2015 - ]
.
OK
All power windows operate normally.
NG → See step 4
OK → END (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY WAS DEFECTIVE)
- Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door). Refer to OPERATION CHECK [08/2015 - ]
.
- REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
- Replace the main body ECU (multiplex network body ECU). Refer to REMOVAL [08/2015 - ] .
NEXT: Go to next step
- CHECK POWER WINDOW CONTROL SYSTEM
- Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door). Refer to OPERATION CHECK [08/2015 - ]
.
OK
All power windows operate normally.
NG → See step 6
OK → END (MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) WAS DEFECTIVE)
- Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door). Refer to OPERATION CHECK [08/2015 - ]
.
- REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [08/2015 - ]