Inspection [10/2014 - ]: Procedure
- INSPECT LUGGAGE DOOR OPENING SWITCH ASSEMBLY (LUGGAGE DOOR OPENING CANCEL SWITCH ASSEMBLY)
- Check the resistance.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (B) - 1 (L) Switch off (Not pressed) 10 kΩ or higher Switch on (Pressed) Below 1 Ω If the result is not as specified, replace the luggage door opening switch assembly (luggage door opening cancel switch assembly).
TEXT IN ILLUSTRATION*a Component without harness connected
(Luggage Door Opening Switch Assembly (Luggage Door Opening Cancel Switch Assembly))
- Measure the resistance according to the value(s) in the table below.
- Check the resistance.