Monitor Description
WARNING: This page is about a different variant/trim than selected.
Based on the signals from the throttle position sensor, air flow meter and crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smooth torque converter engagement. Shift solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short circuit for shift solenoid valve SL, it will illuminate the MIL and store the DTC.