Inspection [12/2012 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT SHIFT SOLENOID VALVE SL
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve SL)Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω If the result is not as specified, replace the shift solenoid valve SL.
- Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition Battery positive (+) → Shift solenoid valve SL connector Valve moves and makes an operating noise Battery negative (-) → Shift solenoid valve SL body If the operation cannot be done as specified, replace the shift solenoid valve SL.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLT
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve SLT, SLU, SL1, SL2, SL3, SL4)Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the result is not as specified, replace the shift solenoid valve SLT.
- Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Terminal 1 Valve moves and makes an operating noise Battery negative (-) → Terminal 2 If the operation cannot be done as specified, replace the shift solenoid valve SLT.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLU
HINT:
Refer to Inspect Shift Solenoid Valve SLT.
- INSPECT SHIFT SOLENOID VALVE SL1
HINT:
Refer to Inspect Shift Solenoid Valve SLT.
- INSPECT SHIFT SOLENOID VALVE SL2
HINT:
Refer to Inspect Shift Solenoid Valve SLT.
- INSPECT SHIFT SOLENOID VALVE SL3
HINT:
Refer to Inspect Shift Solenoid Valve SLT.
- INSPECT SHIFT SOLENOID VALVE SL4
HINT:
Refer to Inspect Shift Solenoid Valve SLT.