Malfunction in Water Temperature Warning Light [08/2015 - ]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check if CAN communication DTCs are output. Refer to DIAGNOSIS SYSTEM [08/2015 - ]
.
Result
Result Proceed to CAN communication DTCs are not output. A CAN communication DTCs are output. B
B → Refer to 10
A: Go to next step
- Check if CAN communication DTCs are output. Refer to DIAGNOSIS SYSTEM [08/2015 - ]
.
- SYSTEM CHECK
- Check the water temperature warning light.
Result
Result Proceed to Water temperature warning light does not come on. A Water temperature warning light remains on. B
B → Refer to 4
A: Go to next step
- Check the water temperature warning light.
- PERFORM ACTIVE TEST USING TECHSTREAM (INDICAT. LAMP COOLANT HOT)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Active Test.
- Perform the Active Test according to the display on the Techstream.COMBINATION METER
Tester Display Test Part Control Range Diagnostic Note Indicat. Lamp Coolant Hot Water temperature warning light OFF or ON - OK
Water temperature warning light operation is normal.
RESULTResult Proceed to OK A NG (w/o Multi-information display) B NG (w/ Multi-information display) C
B → Refer to 8
C → Refer to 14
A: Go to next step
- CHECK FOR DTC
- Check for DTCs. Refer to DTC CHECK / CLEAR [08/2015 - ]
for SFI System. Refer to DTC CHECK / CLEAR [08/2015 - ]
for Meter/Gauge System).
Result
Result Proceed to DTC is not output. A DTC of SFI system is output. B DTC B1503 is output. C
B → Refer to 11
C → Refer to 12
A: Go to next step
- Check for DTCs. Refer to DTC CHECK / CLEAR [08/2015 - ]
for SFI System. Refer to DTC CHECK / CLEAR [08/2015 - ]
for Meter/Gauge System).
- READ VALUE USING TECHSTREAM (COOLANT TEMPERATURE, COOLANT TEMP)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus:
- for Combination Meter: Body Electrical / Combination Meter / Data List.
- for Engine: Powertrain / Engine and ECT / Data List.
- Read the Data List according to the display on the Techstream.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Coolant Temperature Engine coolant temperature / 0 to 127.5°C (0 to 261.5°F) After warming up: 75 to 100°C (167 to 212°F) - ENGINE AND ECTTester Display Measurement Item/Range Normal Condition Stored as Freeze Frame Data Coolant Temp Engine coolant temperature/
Min.: -40°C (-40°F), Max.: 140°C (284°F)75 to 100°C (167 to 212°F): After warming up Yes Diagnostic Note:
This is the engine coolant temperature.
HINT:- After warming up the engine, the engine coolant temperature is 75 to 100°C (167 to 212°F).
- After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature are approximately equal.
- If the value is -40°C (-40°F) or higher than 135°C (275°F), the sensor circuit may be open or shorted.
- Check if the engine overheats when the value indicates higher than 135°C (275°F).
NOTE:Enter inspection mode. Refer to INSPECTION MODE PROCEDURE [08/2015 - ] .
Result
Result Proceed to The data list values of the ECUs do not match (w/o Multi-information display). A The data list values of the ECUs do not match (w/ Multi-information display). B The data list values of the ECUs match. C HINT:
When the Data List values of the ECUs do not match, a signal output error of the ECM is suspected.
B → Refer to 7
C → Refer to 13
A: Go to next step
- REPLACE METER CIRCUIT PLATE
- Replace the meter circuit plate with a new or a known good one. Refer to DISASSEMBLY [08/2015 - ]
.
OK
The operation of the water temperature warning light returns to normal.
NG → Refer to 9
OK → END
- Replace the meter circuit plate with a new or a known good one. Refer to DISASSEMBLY [08/2015 - ]
.
- REPLACE COMBINATION METER SUB-ASSEMBLY
- Replace the combination meter sub-assembly with a new or a known good one. Refer to REMOVAL [08/2015 - ]
.
OK
The operation of the water temperature warning light returns to normal.
NG → Refer to 9
OK → END
- Replace the combination meter sub-assembly with a new or a known good one. Refer to REMOVAL [08/2015 - ]
.
- REPLACE METER CIRCUIT PLATE. Refer to DISASSEMBLY [08/2015 - ]
- REPLACE ECM. Refer to REMOVAL [08/2015 - ]
- GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ]
- GO TO SFI SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ]
- GO TO METER / GAUGE SYSTEM. Refer to DTC B1503: Exhaust Heat Management Warning Detected [08/2015 - ]
- GO TO SFI SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ]
- REPLACE COMBINATION METER SUB-ASSEMBLY. Refer to REMOVAL [08/2015 - ]