ECM Power Source Circuit [11/2016 - ]: Procedure
- CHECK TERMINAL VOLTAGE (POWER SOURCE OF SEMICONDUCTOR PWR INTEGRATION ECU)
*1 No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly - Disconnect the semiconductor pwr integration ECU connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition B-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result: 3
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (AUXILIARY BATTERY - SEMICONDUCTOR PWR INTEGRATION ECU)
Result: 1
OK
See step 2
- CHECK HARNESS AND CONNECTOR (SEMICONDUCTOR PWR INTEGRATION ECU - BODY GROUND)
- Disconnect the semiconductor pwr integration ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1D-14 - Body ground Always Below 1 Ω 1G-5 - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 3
- INSPECT SEMICONDUCTOR PWR INTEGRATION ECU (EFI MAIN RELAY, IG2 RELAY)
- Inspect the semiconductor pwr integration ECU (EFI MAIN relay, IG2 relay).
Refer to INSPECTION [02/2014 - ]
Result
Proceed to OK NG
Result: 2
NG
REPLACE SEMICONDUCTOR PWR INTEGRATION ECU. Refer to REMOVAL [02/2014 - ]
Result: 1
OK
See step 4
- Inspect the semiconductor pwr integration ECU (EFI MAIN relay, IG2 relay).
- CHECK HARNESS AND CONNECTOR (SEMICONDUCTOR PWR INTEGRATION ECU - ECM)
- Disconnect the semiconductor pwr integration ECU connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1G-4 - A43-6 (IGSW) Always Below 1 Ω 1G-6 - A43-46 (MREL) Always Below 1 Ω 1G-1 - A43-2 (+B) Always Below 1 Ω 1G-2 - A43-3 (+B2) Always Below 1 Ω 1G-4 or A43-6 (IGSW) - Body ground and other terminals Always 10 kΩ or higher 1G-6 or A43-46 (MREL) - Body ground and other terminals Always 10 kΩ or higher 1G-1 or A43-2 (+B) - Body ground and other terminals Always 10 kΩ or higher 1G-2 or A43-3 (+B2) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 5
- CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C1-53 (E1) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 6
- INSPECT ECM (IGSW VOLTAGE)
*a Front view of wire harness connector
(to ECM)- Disconnect the ECM connector.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A43-6 (IGSW) - Body ground Power switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result: 1
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [11/2016 - ]
Result: 3
NG
See step 7
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) - SEMICONDUCTOR PWR INTEGRATION ECU)
- Disconnect the certification ECU (smart key ECU assembly) connector.
- Disconnect the semiconductor pwr integration ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F9-3 (IG1D) - 1E-1 Always Below 1 Ω F9-3 (IG1D) or 1E-1 - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
GO TO SMART KEY SYSTEM (for Start Function). Refer to HOW TO PROCEED WITH TROUBLESHOOTING [02/2014 - ]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR