Installation [02/2014 - 11/2016]: Procedure
- INSTALL HEATED OXYGEN SENSOR (for Bank 1)
HINT:
Perform "Inspection After Repair" after replacing a heated oxygen sensor.
Refer to INITIALIZATION [02/2014 - 11/2016]
- Using SST, install the heated oxygen sensor to the front No. 3 exhaust pipe sub-assembly.
*a Length of SST 30 mm (1.18 in.) *b Length of Torque Wrench 260 mm (10.2 in.) - SST: 09224-00010
without SST [Torque (N*m (kgf*cm, ft.*lbf))]
Torque: 44 N*m (449 kgf*cm, 32 ft.*lbf)
with SST [Reading of Torque wrench (N*m (kgf*cm, ft.*lbf))]
Torque: 39 N*m (398 kgf*cm, 29 ft.*lbf)
NOTE:If the heated oxygen sensor has been struck or dropped, replace it.
HINT:
- This torque value is effective when SST is parallel to the torque wrench.
- The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
- The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).
- If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
Refer to PRECAUTION [02/2014 - 11/2016]
- Connect the heated oxygen sensor connector.
- Engage the 3 wire harness clamps.
- Using SST, install the heated oxygen sensor to the front No. 3 exhaust pipe sub-assembly.
- INSTALL FRONT FLOOR COVER LH
Refer to PROCEDURE - Step 14
- INSTALL HEATED OXYGEN SENSOR (for Bank 2)
HINT:
Perform "Inspection After Repair" after replacing a heated oxygen sensor.
Refer to INITIALIZATION [02/2014 - 11/2016]
- Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.
- SST: 09224-00010
without SST [Torque (N*m (kgf*cm, ft.*lbf))]
Torque: 44 N*m (449 kgf*cm, 32 ft.*lbf)
with SST [Reading of Torque wrench (N*m (kgf*cm, ft.*lbf))]
Torque: 39 N*m (398 kgf*cm, 29 ft.*lbf)
NOTE:If the heated oxygen sensor has been struck or dropped, replace it.
HINT:
- This torque value is effective when SST is parallel to the torque wrench.
- The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
- The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).
- If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
Refer to PRECAUTION [02/2014 - 11/2016]
*a Length of SST 30 mm (1.18 in.) *b Length of Torque Wrench 260 mm (10.2 in.) - Connect the heated oxygen sensor connector.
- Engage the 3 wire harness clamps.
- Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.
- INSPECT FOR EXHAUST GAS LEAK
Refer to PROCEDURE - Step 14
- PERFORM INITIALIZATION
- Perform "Inspection After Repair" after replacing a heated oxygen sensor.
Refer to INITIALIZATION [02/2014 - 11/2016]
- Perform "Inspection After Repair" after replacing a heated oxygen sensor.