LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2016 >> Highlander Hybrid Limited >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System (2GR-FXE) - Diagnostic Codes (4 Of 7) >> Hybrid Control System >> DTC P0A92-521: Hybrid Generator Performance [02/2014 - 11/2015] >> Description

DTC P0A92-521: Hybrid Generator Performance [02/2014 - 11/2015]: Description

For a description of the generator (MG1).

Refer to DESCRIPTION 

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A92-521 Hybrid Generator Performance Generator system malfunction:
If current does not flow as commanded, the generator high voltage system may be malfunctioning.
Malfunction is detected when the vehicle is stopped or the engine is starting.
(1 trip detection logic)
  • Hybrid vehicle generator assembly
  • Inverter with converter assembly
  • Wire harness or connector
  • Power management control ECU
Comes on Master Warning Light:
Comes on

Suspected malfunctioning parts: