Home >> Toyota >> 2016 >> Highlander Hybrid Limited >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System (2GR-FXE) - Diagnostic Codes (4 Of 7) >> Hybrid Control System >> DTC P0A7A-517: Generator Inverter Performance; DTC P0A7A-809: Generator Inverter Performance [02/2014 - 11/2016] >> Description

DTC P0A7A-517: Generator Inverter Performance; DTC P0A7A-809: Generator Inverter Performance [02/2014 - 11/2016]: Description

For a description of the inverter.

Refer to DESCRIPTION

If a circuit malfunction, overheating or an internal short circuit of the generator inverter is detected, a signal is sent from the inverter with converter assembly to the MG ECU via the inverter fail signal line.

If an abnormal amount of current flows through the generator inverter, the MG ECU detects it and sends a signal to inform the power management control ECU of the malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A7A-517 Generator Inverter Performance Generator inverter fail signal detected (MG ECU malfunction):
Overcurrent occurs in the generator inverter.*
(1 trip detection logic)
  • Inverter with converter assembly
  • Wire harness or connector
Comes on Master Warning Light:
Comes on
P0A7A-809 Generator Inverter Performance Abnormal generator inverter current (overcurrent) detected (MG ECU malfunction)
(1 trip detection logic)
  • Inverter with converter assembly
  • Wire harness or connector
Comes on Master Warning Light:
Comes on

*: The MG ECU, which is built into in the inverter with converter assembly, can be suspected as a main cause of the malfunction.