Home >> Toyota >> 2016 >> Highlander Hybrid Limited >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System (2GR-FXE) - Diagnostic Codes (3 Of 7) >> Hybrid Control System >> DTC P0C3E-628: DC / DC Converter Temperature Sensor "B" Range / Performance; DTC P0C41-627: DC / DC Converter Temperature Sensor "B" Intermittent / Erratic [02/2014 - 11/2016] >> Description

DTC P0C3E-628: DC / DC Converter Temperature Sensor "B" Range / Performance; DTC P0C41-627: DC / DC Converter Temperature Sensor "B" Intermittent / Erratic [02/2014 - 11/2016]: Description

The MG ECU, which is built into in the inverter with converter assembly, detects the temperature of the boost converter using the temperature sensor built into the boost converter. If necessary, the MG ECU will limit inverter output to help prevent boost converter overheating. The power management control ECU also detects malfunctions in the sensor based on the temperature sensor values. The inverter with converter assembly detects malfunctions in the boost converter temperature sensor and its wiring.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0C3E-628 DC / DC Converter Temperature Sensor "B" Range / Performance Boost converter temperature (lower) calculated by the power management control ECU is different from the actual temperature for 10 seconds or more, and the boost converter temperature (lower) is excessively high.
(1 trip detection logic)
  • Inverter cooling system
  • Cooling fan system
  • Inverter with converter assembly
  • Wire harness or connector
Does not come on Master Warning Light:
Comes on
P0C41-627 DC / DC Converter Temperature Sensor "B" Intermittent / Erratic Sudden change in boost converter temperature sensor (lower) output or hunting:
Either of the following conditions is met:
  1. Unusual sudden change in boost converter temperature sensor (lower) output occurs and the offset continues for a certain period of time.*
  2. Unusual sudden change in boost converter temperature sensor (lower) output occurs repeatedly.*

(1 trip detection logic)
  • Inverter cooling system
  • Cooling fan system
  • Inverter with converter assembly
  • Wire harness or connector
Does not come on Master Warning Light:
Comes on

HINT: 

*: If only DTC P0C41-627 is output, a temperature sensor malfunction is more likely to be the cause than a sudden change in actual temperature.

RELATED DATA LIST

DTC No. Data List
P0C3E-628
  • DC/DC Cnv Temp (Upper)
  • DC/DC Cnv Temp (Lower)
P0C41-627

The following items can be helpful when performing repairs:

Operation History Data