DTC P0A94-550: DC / DC Converter Performance; DTC P0A94-564: DC / DC Converter Performance [02/2014 - 11/2016]: Procedure
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 1
A
REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 3
B
CONNECT SECURELY
Result: 4
C
REPAIR OR REPLACE HARNESS OR CONNECTOR