LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2016 >> Highlander Hybrid Limited >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System - Diagnostic Codes & Circuit Tests - (Hybrid) >> Air Conditioning System >> DTC B14AA: Glass Humidity Sensor Circuit [02/2014 - ] >> Procedure

DTC B14AA: Glass Humidity Sensor Circuit [02/2014 - ]: Procedure

  1. READ VALUE USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.
    5. Check the value(s) by referring to the table below.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Glass Humidity Glass humidity Min.: 0.00%
      Max.: 100.00%
      Actual glass humidity is displayed -

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Glass Humidity

      OK

      The display is as specified in the normal condition column.

      Result

      Result  Proceed to
      NG A
      OK (When troubleshooting according to Problem Symptoms Table) B
      OK (When troubleshooting according to the DTC) C

    Result:  2

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [02/2014 - 11/2016]  Refer to  PROBLEM SYMPTOMS TABLE [11/2016 - ] 

    Result:  3

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [02/2014 - ] 

    Result:  1

    See step  2

  2. CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT) 
    1. Disconnect the S14 air conditioning thermistor assembly (glass humidity sensor) connector.
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      S14-5 (S5V) - Body ground Power switch off Below 1 V
      S14-5 (S5V) - Body ground Power switch on (IG) 4.5 to 5.5 V

      Result

      Proceed to
      OK
      NG

    Result:  2

    NG 

    See step  4

    Result:  1

    OK 

    See step  3

  3. INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR) 
    1. Reconnect the air conditioning thermistor assembly (glass humidity sensor) connector.
      GTY440053Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component without harness connected
      (Air Conditioning Thermistor Assembly (Glass Humidity Sensor))
      *b Sensing Portion
      *c Voltage (V) *d Relative Humidity (%)
    2. Turn the power switch on (IG).
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      1 (SEG3) - 3 (RH) 5 to 15 % 1.01 V
      15 to 25 % 1.37 V
      25 to 35 % 1.73 V
      35 to 45 % 2.09 V
      45 to 55 % 2.45 V
      55 to 65 % 2.81 V
      65 to 75 % 3.17 V
      75 to 85 % 3.53 V
      85 to 95 % 3.89 V
      NOTE:
      • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
      • The output voltage at an ambient temperature of 25°C (77°F) is shown above.

      HINT: 

      As the humidity increases, the voltage increases (see the graph).

      Result

      Proceed to
      OK
      NG

    Result:  2

    NG 

    REPLACE AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS TEMPERATURE SENSOR). Refer to  REMOVAL [02/2014 - ] 

    Result:  1

    OK 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY) 
    1. Disconnect the S14 air conditioning thermistor assembly (glass humidity sensor) connector.
    2. Disconnect the F80 air conditioning amplifier assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      S14-3 (RH) - F80-28 (RH) Always Below 1 Ω
      S14-3 (RH) - Body ground Always 10 kΩ or higher
      S14-1 (SEG3) - F80-35 (SG-5) Always Below 1 Ω
      S14-1 (SEG3) - Body ground Always 10 kΩ or higher
      S14-5 (S5V) - F80-31 (S5-4) Always Below 1 Ω
      S14-5 (S5V) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result:  1

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [02/2014 - ] 

    Result:  2

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR