DTC B14AA: Glass Humidity Sensor Circuit [02/2014 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Check the value(s) by referring to the table below.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Glass Humidity Glass humidity Min.: 0.00%
Max.: 100.00%Actual glass humidity is displayed - Body Electrical > Air Conditioner > Data List
Tester Display Glass Humidity OK
The display is as specified in the normal condition column.
Result
Result Proceed to NG A OK (When troubleshooting according to Problem Symptoms Table) B OK (When troubleshooting according to the DTC) C
Result: 2
B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [02/2014 - 11/2016] Refer to PROBLEM SYMPTOMS TABLE [11/2016 - ]
Result: 3
C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 1
A
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the S14 air conditioning thermistor assembly (glass humidity sensor) connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition S14-5 (S5V) - Body ground Power switch off Below 1 V S14-5 (S5V) - Body ground Power switch on (IG) 4.5 to 5.5 V Result
Proceed to OK NG
Result: 2
NG
See step 4
Result: 1
OK
See step 3
- INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR)
- Reconnect the air conditioning thermistor assembly (glass humidity sensor) connector.
*a Component without harness connected
(Air Conditioning Thermistor Assembly (Glass Humidity Sensor))*b Sensing Portion *c Voltage (V) *d Relative Humidity (%) - Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 1 (SEG3) - 3 (RH) 5 to 15 % 1.01 V 15 to 25 % 1.37 V 25 to 35 % 1.73 V 35 to 45 % 2.09 V 45 to 55 % 2.45 V 55 to 65 % 2.81 V 65 to 75 % 3.17 V 75 to 85 % 3.53 V 85 to 95 % 3.89 V NOTE:- Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
- The output voltage at an ambient temperature of 25°C (77°F) is shown above.
HINT:
As the humidity increases, the voltage increases (see the graph).
Result
Proceed to OK NG
Result: 2
NG
REPLACE AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS TEMPERATURE SENSOR). Refer to REMOVAL [02/2014 - ]
Result: 1
OK
See step 4
- Reconnect the air conditioning thermistor assembly (glass humidity sensor) connector.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the S14 air conditioning thermistor assembly (glass humidity sensor) connector.
- Disconnect the F80 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition S14-3 (RH) - F80-28 (RH) Always Below 1 Ω S14-3 (RH) - Body ground Always 10 kΩ or higher S14-1 (SEG3) - F80-35 (SG-5) Always Below 1 Ω S14-1 (SEG3) - Body ground Always 10 kΩ or higher S14-5 (S5V) - F80-31 (S5-4) Always Below 1 Ω S14-5 (S5V) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR