DTC B1423/23: Pressure Sensor Circuit [11/2016 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the A13 air conditioner tube and accessory assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A13-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V Result
Proceed to OK NG
Result: 2
NG
See step 18
Result: 1
OK
See step 2
- CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A13-1 (-) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 2
NG
See step 17
Result: 1
OK
See step 3
- Measure the resistance according to the value(s) in the table below.
- INSPECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY (SENSOR SIGNAL CIRCUIT)
*a Component with harness connected
(Air Conditioning Amplifier Assembly)- Connect the A13 air conditioner tube and accessory assembly connector.
- Remove the air conditioning amplifier assembly with the connectors still connected.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F80-9 (PRE) - Body ground Power switch on (IG)
(A/C switch: Off)0.74 to 4.71 V HINT:
If the voltage is not as specified, there may be a malfunction in the air conditioning amplifier assembly, air conditioner tube and accessory assembly, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.
Result
Proceed to OK NG
Result: 2
NG
See step 11
Result: 1
OK
See step 4
- INSPECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY (SENSOR SIGNAL CIRCUIT)
- Measure the voltage when the following conditions are met.MEASUREMENT CONDITION:
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch RECIRCULATION Interior temperature 25 to 35°C (77 to 95°F) NOTE:- If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.71 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
- It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
HINT:
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
- Measure the voltage according to the value(s) in the table below.
*a Component with harness connected
(Air Conditioning Amplifier Assembly)Standard Voltage
Tester Connection Condition Specified Condition F80-9 (PRE) - Body ground Power switch on (IG)
(A/C switch: On)0.74 to 4.71 V
Result
Result Proceed to OK (When troubleshooting according to DTC) A OK (When troubleshooting according to Problem Symptoms Table) B NG C
Result: 1
A
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [11/2016 - ]
Result: 3
C
See step 5
- Measure the voltage when the following conditions are met.
- INSPECT COOLING FAN SYSTEM
- Check if the cooling fan operates normally.
Refer to ON-VEHICLE INSPECTION [11/2016 - ]
Result
Proceed to OK NG
Result: 2
NG
GO TO COOLING FAN SYSTEM. Refer to ON-VEHICLE INSPECTION [11/2016 - ]
Result: 1
OK
See step 6
- Check if the cooling fan operates normally.
- CHARGE SYSTEM WITH REFRIGERANT
- Use a refrigerant recovery unit to recover refrigerant.
- Evacuate the air conditioning system.
- Add an appropriate amount of refrigerant.
Refer to REPLACEMENT [02/2014 - ]
HINT:
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.
Result:
NEXT
- RECHECK FOR DTC
- Recheck for DTCs when the following conditions are met.MEASUREMENT CONDITION:
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch RECIRCULATION Interior temperature 25 to 35°C (77 to 95°F) Body Electrical > Air Conditioner > Trouble Codes
NOTE:If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.
HINT:
- When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
- If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output after this work, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.
Result
Result Proceed to DTC B1423/23 is not output A DTC B1423/23 is output B
Result: 1
A
REPLACE COOLER CONDENSER ASSEMBLY. Refer to REMOVAL [11/2016 - ]
Result: 2
B
See step 8
- Recheck for DTCs when the following conditions are met.
- REPLACE COOLER EXPANSION VALVE
- Replace the cooler expansion valve with a new or known good one.
Refer to REMOVAL [02/2014 - ]
HINT:
Replace the cooler expansion valve with a new or known good one because the cooler expansion valve is either stuck or clogged.
Result:
NEXT
- Replace the cooler expansion valve with a new or known good one.
- CHARGE SYSTEM WITH REFRIGERANT
- Use a refrigerant recovery unit to recover refrigerant.
- Evacuate the air conditioning system.
- Add an appropriate amount of refrigerant.
Refer to REPLACEMENT [02/2014 - ]
HINT:
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.
Result:
NEXT
- RECHECK FOR DTC
- Recheck for DTCs when the following conditions are met.MEASUREMENT CONDITION:
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch RECIRCULATION Interior temperature 25 to 35°C (77 to 95°F) Body Electrical > Air Conditioner > Trouble Codes
NOTE:If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.
HINT:
- When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
- If refrigerant pressure is not normal after replacing the cooler expansion valve with a new or known good one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the cooler condenser assembly or pipes.
Result
Result Proceed to DTC B1423/23 is not output A DTC B1423/23 is output B
Result: 1
A
END
Result: 2
B
CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY OR PIPE
- Recheck for DTCs when the following conditions are met.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the A13 air conditioner tube and accessory assembly connector.
- Disconnect the F80 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A13-2 (PR) - F80-9 (PRE) Always Below 1 Ω A13-2 (PR) or F80-9 (PRE) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 12
- INSPECT FOR AIR CONDITIONING SYSTEM LEAK
- Install a manifold gauge set.
- Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
- Evacuate the air conditioning system and check that vacuum can be maintained.
OK
Vacuum can be maintained in the air conditioning system.
HINT:
If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.
Result
Proceed to OK NG
Result: 3
NG
See step 16
Result: 1
OK
See step 13
- CHARGE SYSTEM WITH REFRIGERANT
- Use a refrigerant recovery unit to recover refrigerant.
- Evacuate the air conditioning system.
- Add an appropriate amount of refrigerant.
Refer to REPLACEMENT [02/2014 - ]
HINT:
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.
Result:
NEXT
- RECHECK FOR DTC
- Recheck for DTCs when the following conditions are met.MEASUREMENT CONDITION:
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch RECIRCULATION Interior temperature 25 to 35°C (77 to 95°F) Body Electrical > Air Conditioner > Trouble Codes
NOTE:If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.
HINT:
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Result
Result Proceed to DTC B1423/23 is not output A DTC B1423/23 is output B NOTE:If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding too much refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.
Result: 1
A
END
Result: 2
B
See step 15
- Recheck for DTCs when the following conditions are met.
- INSPECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
*a Component with harness connected
(Air Conditioning Amplifier Assembly)- Install a manifold gauge set.
- Connect the A13 air conditioner tube and accessory assembly connector.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F80-9 (PRE) - F80-13 (SG-2) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2 , 439 psi) and more than 176 kPa (1.8 kgf/cm2 , 26 psi)) 0.74 to 4.71 V Result
Proceed to OK NG
Result: 1
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
NG
REPLACE AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
- REPAIR AIR CONDITIONING SYSTEM LEAK
- Identify the area where refrigerant leaks from.
Refer to REPLACEMENT [02/2014 - ]
- Repair the identified area of the air conditioning system.
- Evacuate the air conditioning system.
Result:
NEXT
CHARGE SYSTEM WITH REFRIGERANT. Refer to REPLACEMENT [02/2014 - ]
- Identify the area where refrigerant leaks from.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the F80 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A13-1 (-) - F80-13 (SG-2) Always Below 1 Ω A13-1 (-) or F80-13 (SG-2) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the F80 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A13-3 (+) - F80-10 (S5-3) Always Below 1 Ω A13-3 (+) or F80-10 (S5-3) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR