DTC B1412/12: Ambient Temperature Sensor Circuit [11/2016 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Check the value(s) by referring to the table below.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed - Body Electrical > Air Conditioner > Data List
Tester Display Ambient Temp Sensor OK
The display is as specified in the normal condition column.
Result
Proceed to OK NG
Result: 1
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
NG
See step 2
- INSPECT THERMISTOR ASSEMBLY
*a Component without harness connected
(Thermistor Assembly)*b Sensing Portion *c Resistance (kΩ) *d Temperature (°C (°F)) *e Allowable Range - Remove the thermistor assembly.
Refer to REMOVAL [02/2014 - ]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (+) - 1 (-) 10°C (50°F) 3.00 to 3.73 kΩ 15°C (59°F) 2.45 to 2.88 kΩ 20°C (68°F) 1.95 to 2.30 kΩ 25°C (77°F) 1.60 to 1.80 kΩ 30°C (86°F) 1.28 to 1.47 kΩ 35°C (95°F) 1.00 to 1.22 kΩ 40°C (104°F) 0.80 to 1.00 kΩ 45°C (113°F) 0.65 to 0.85 kΩ 50°C (122°F) 0.50 to 0.70 kΩ 55°C (131°F) 0.44 to 0.60 kΩ 60°C (140°F) 0.36 to 0.50 kΩ NOTE:- Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph).
Result
Proceed to OK NG
Result: 2
NG
REPLACE THERMISTOR ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 1
OK
See step 3
- Remove the thermistor assembly.
- CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the F80 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A79-2 (+) - F80-5 (TAM) Always Below 1 Ω A79-1 (-) - F80-13 (SG-2) Always Below 1 Ω A79-2 (+) or F80-5 (TAM) - Body ground Always 10 kΩ or higher A79-1 (-) or F80-13 (SG-2) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR