Home >> Toyota >> 2016 >> Highlander Hybrid Limited >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System - Diagnostic Codes & Circuit Tests - (Hybrid) >> Air Conditioning System >> DTC B1412/12: Ambient Temperature Sensor Circuit [11/2016 - ] >> Procedure

DTC B1412/12: Ambient Temperature Sensor Circuit [11/2016 - ]: Procedure

  1. READ VALUE USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.
    5. Check the value(s) by referring to the table below.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
      Max.: 65.95°C (150.71°F)
      Actual ambient temperature displayed -

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Ambient Temp Sensor

      OK

      The display is as specified in the normal condition column.

      Result

      Proceed to
      OK
      NG

    Result:  1

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [02/2014 - ] 

    Result:  2

    NG 

    See step  2

  2. INSPECT THERMISTOR ASSEMBLY 
    GTY719165Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    *a Component without harness connected
    (Thermistor Assembly)
    *b Sensing Portion
    *c Resistance (kΩ)
    *d Temperature (°C (°F))
    *e Allowable Range
    1. Remove the thermistor assembly.

      Refer to REMOVAL [02/2014 - ]

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      2 (+) - 1 (-) 10°C (50°F) 3.00 to 3.73 kΩ
      15°C (59°F) 2.45 to 2.88 kΩ
      20°C (68°F) 1.95 to 2.30 kΩ
      25°C (77°F) 1.60 to 1.80 kΩ
      30°C (86°F) 1.28 to 1.47 kΩ
      35°C (95°F) 1.00 to 1.22 kΩ
      40°C (104°F) 0.80 to 1.00 kΩ
      45°C (113°F) 0.65 to 0.85 kΩ
      50°C (122°F) 0.50 to 0.70 kΩ
      55°C (131°F) 0.44 to 0.60 kΩ
      60°C (140°F) 0.36 to 0.50 kΩ
      NOTE:
      • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
      • When measuring, the sensor temperature must be the same as the ambient temperature.

      HINT: 

      As the temperature increases, the resistance decreases (see the graph).

      Result

      Proceed to
      OK
      NG

    Result:  2

    NG 

    REPLACE THERMISTOR ASSEMBLY. Refer to  REMOVAL [02/2014 - ] 

    Result:  1

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY) 
    1. Disconnect the F80 air conditioning amplifier assembly connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      A79-2 (+) - F80-5 (TAM) Always Below 1 Ω
      A79-1 (-) - F80-13 (SG-2) Always Below 1 Ω
      A79-2 (+) or F80-5 (TAM) - Body ground Always 10 kΩ or higher
      A79-1 (-) or F80-13 (SG-2) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result:  1

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [02/2014 - ] 

    Result:  2

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR