IG Power Source Circuit [02/2014 - 11/2016]: Procedure
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - IG POWER SOURCE)
- Disconnect the F80 and F81 air conditioning amplifier assembly connectors.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F80-1 (IG+) - Body ground Power switch off Below 1 V F80-1 (IG+) - Body ground Power switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 2
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F80-14 (GND) - Body ground Always Below 1 Ω F81-24 (GND2) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 1
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [02/2014 - 11/2016]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Measure the resistance according to the value(s) in the table below.