DTC P0E71-344: Generator Torque Delivered Performance [11/2016 - ]: Description
WARNING: This page is about a different car, the 2019 Toyota Highlander, 2018 Toyota Highlander, and 2017 Toyota Highlander. However, it is still accessible from the selected car via links, so may be relevant.
For a description of the inverter.
Refer to DESCRIPTION
When the actual generator torque is different from the generator torque requested by the MG ECU, the hybrid vehicle control ECU assembly stores this DTC.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0E71-344 | Generator Torque Delivered Performance | Generator (MG1) torque execution monitoring malfunction: The difference between the generator torque requested by the Hybrid vehicle control ECU assembly and actual motor torque is large. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
RELATED DATA LIST
| DTC No. | Data List |
|---|---|
| P0E71-344 |
|