LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2016 >> Highlander Hybrid Limited >> Repair and Diagnosis >> Engine Performance >> System >> SFI System [2GR-FXE] - Diagnostic Codes - (Hybrid) (2 Of 3) >> SFI System >> DTC P0116: Engine Coolant Temperature Circuit Range / Performance [02/2014 - 11/2016] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

COLD START MONITOR

Engine coolant temperature sensor value change Less than 5°C (9°F)
SOAK MONITOR

Difference between current engine coolant temperature sensor value and previous engine coolant temperature sensor value when engine stopped Less than 5°C (9°F) (varies with engine coolant temperature of last trip engine stop)