On-Vehicle Inspection [02/2014 - 11/2016]: Procedure
- INSPECT FAN NO. 1 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the FAN NO. 1 relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT FAN NO. 2 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the FAN NO. 2 relay.
- Measure the resistance according to the value(s) in the table below.