On-Vehicle Inspection [02/2014 - 11/2016]: Procedure
- CHECK COOLING FAN SYSTEM
- Check and ensure the following conditions:
- The power switch is off.
- The engine coolant temperature is less than 94°C (201°F).
- The auxiliary battery voltage is between 11 to 14 V.
- The A/C switch is off.
- Connect the pickup of a clamp-on ammeter around one of the 2 wires for the cooling fan motor.
- Turn the power switch ON (IG) and wait for approximately 10 seconds. Check that the fan is not operating.
- Start the engine. Check that the fan is not operating with the engine idling.
HINT:
- Make sure that the engine coolant temperature is less than 94°C (201°F).
- Turn the A/C switch off.
- Check that the fan operates when the A/C switch is turned on.
- Measure the current while the cooling fan motor is turning.
Standard Current
Item Condition Specified Condition Cooling fan motor Auxiliary battery voltage applied at 20°C (68°F) 15.0 to 21.0 A No. 2 cooling fan motor 15.0 to 21.0 A HINT:
The engine coolant temperature should be less than 94°C (201°F).
- Check that the fan operates when the water temperature sensor connector is disconnected.
- Measure the current while the cooling fan motor is turning.
Standard Current
Item Condition Specified Condition Cooling fan motor Auxiliary battery voltage applied at 20°C (68°F) 15.0 to 21.0 A No. 2 cooling fan motor 15.0 to 21.0 A - After the engine is warmed up, check that the fan operates as shown in the illustration.
*a Operating Diagram *b MAX HI *c HI *d LO *e OFF *f Fan Speed HINT:
- The engine coolant temperature at which the fan starts operating is approximately 96°C (205°F).
- This system can also be checked using the Techstream.
Enter the following menus: Powertrain / Engine / Data List / Coolant Temp.
Powertrain > Engine > Data List
Tester Display Coolant Temp
- Check and ensure the following conditions: