Entire Combination Meter Does Not Operate [11/2016 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BODY GROUND)
- Disconnect the F124 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F124-31 (E2) - Body ground Always Below 1 Ω F124-31 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F124-21 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V F124-21 (B) - Body ground Power switch off 11 to 14 V Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY:
Refer to REMOVAL [02/2014 - ] .
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR