Inspection [02/2014 - ]: Procedure
- INSPECT FUEL LID WITH LOCK MOTOR ASSEMBLY
- Check the operation of the fuel lid with lock motor assembly.
- Apply auxiliary battery voltage to the fuel lid with lock motor assembly connector, and check that the fuel lid with lock motor assembly operates smoothly as follows.
OK
Auxiliary Battery Connection Specified Condition Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 2Unlock If the result is not as specified, replace the fuel lid with lock motor assembly.
*a Component without harness connected
(Fuel Lid with Lock Motor Assembly)*b Shaft Stroke *c Lock *d Unlock - Measure the shaft stroke.
OK
Area Condition Specified Condition Shaft stroke Unlock 0 mm
(0 in.)Lock 10 mm
(0.394 in.)If the result is not as specified, replace the fuel lid with lock motor assembly.
- Apply auxiliary battery voltage to the fuel lid with lock motor assembly connector, and check that the fuel lid with lock motor assembly operates smoothly as follows.
- Check the operation of the fuel lid with lock motor assembly.