On-Vehicle Inspection [02/2014 - ]: Procedure
- INSPECT G/H NO. 1 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 4 Auxiliary battery voltage applied to terminals 1 and 2 10 kΩ or higher 3 - 4 Auxiliary battery voltage not applied between terminals Below 1 Ω 3 - 5 Auxiliary battery voltage applied to terminals 1 and 2 Below 1 Ω 3 - 5 Auxiliary battery voltage not applied between terminals 10 kΩ or higher 4 - 5 Always 10 kΩ or higher If the result is not as specified, replace the G/H No. 1 relay.
- Measure the resistance according to the value(s) in the table below.