Interior Light Circuit [02/2014 - ]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Illuminated Entry System Turns on the lights that are controlled by the illuminated entry system* ON or OFF Perform the Active Test with interior light DOOR switch in the map light assembly turned on. - *: Refer to Description for the lights that are controlled by the illuminated entry system.
Refer to DESCRIPTION
Body Electrical > Main Body > Active Test
Tester Display Illuminated Entry System OK
All lights that are controlled by the illuminated entry system come on.
Result
Proceed to OK NG - *: Refer to Description for the lights that are controlled by the illuminated entry system.
Result: 1
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [02/2014 - ]
Result: 3
NG
See step 2
- INSPECT MAP LIGHT ASSEMBLY
- Remove the map light assembly.
Refer to REMOVAL [02/2014 - ]
- Inspect the map light assembly.
Refer to INSPECTION [02/2014 - ]
Result
Proceed to OK NG
Result: 2
NG
REPLACE MAP LIGHT ASSEMBLY. Refer to REMOVAL [02/2014 - ]
Result: 1
OK
See step 3
- Remove the map light assembly.
- CHECK HARNESS AND CONNECTOR (MAP LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 4D instrument panel junction block connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4D-12 - S1-9 (CTY) Always Below 1 Ω 4D-12 or S1-9 (CTY) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 4
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly.
Refer to REMOVAL [02/2014 - 11/2016] Refer to REMOVAL [11/2016 - ]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Refer to REMOVAL [02/2014 - 11/2016] Refer to REMOVAL [11/2016 - ]
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 4D-12 - MB-1 (ILE) Always Below 1 Ω Result
Proceed to OK NG
Result: 1
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [02/2014 - 11/2016] Refer to REMOVAL [11/2016 - ]
Result: 2
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [02/2014 - 11/2016] Refer to REMOVAL [11/2016 - ]
- Remove the instrument panel junction block assembly.