Back-up Light Circuit [11/2016 - ]: Procedure
- CHECK FOR DTC (HYBRID CONTROL SYSTEM)
- Clear the DTCs.
Refer to DTC CHECK / CLEAR [11/2016 - ]
Powertrain > Hybrid Control > Clear DTCs
- Check for DTCs.
Refer to DTC CHECK / CLEAR [11/2016 - ]
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to Hybrid control system DTCs are not output A Hybrid control system DTCs are output B
Result: 2
B
GO TO HYBRID CONTROL SYSTEM (DIAGNOSTIC TROUBLE CODE CHART). Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2016 - 10/2017] Refer to DIAGNOSTIC TROUBLE CODE CHART [10/2017 - ]
Result: 1
A
See step 2
- Clear the DTCs.
- INSPECT BACK UP LP RELAY
*a Component without harness connected
(BACK UP LP Relay)- Remove the BACK UP LP Relay from the No. 1 engine room relay block and No. 1 junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Result
Proceed to OK NG
Result: 2
NG
REPLACE BACK UP LP RELAY
Result: 1
OK
See step 3
- CHECK HARNESS AND CONNECTOR (BACK UP LP RELAY POWER SOURCE AND BODY GROUND)
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 3 (BACK UP LP relay) - Body ground Power switch on (IG) 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (BACK UP LP relay) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 4
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (BACK UP LP RELAY - REAR LIGHT ASSEMBLY LH AND REAR LIGHT ASSEMBLY RH)
- Disconnect the X4 rear light assembly LH connector.
- Disconnect the X28 rear light assembly RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 5 (BACK UP LP relay) - X4-1 (B) Always Below 1 Ω 5 (BACK UP LP relay) - X28-1 (B) Always Below 1 Ω 5 (BACK UP LP relay) or X4-1 (B) - Body ground Always 10 kΩ or higher 5 (BACK UP LP relay) or X28-1 (B) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 5
- CHECK HARNESS AND CONNECTOR (BACK UP LP RELAY - HYBRID VEHICLE CONTROL ECU ASSEMBLY)
- Disconnect the A86 hybrid vehicle control ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (BACK UP LP relay) - A86-2 (BL) Always Below 1 Ω 1 (BACK UP LP relay) or A86-2 (BL) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE HYBRID VEHICLE CONTROL ECU ASSEMBLY. Refer to REMOVAL [11/2016 - ]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR