Inspection [02/2014 - 11/2016]: Procedure
- INSPECT DAYTIME RUNNING LIGHT ASSEMBLY LH
- Apply auxiliary battery voltage to the daytime running light assembly LH and check that the light comes on.
*a Component without harness connected
(Daytime Running Light Assembly LH)OK
Condition Specified Condition Auxiliary battery positive (+) → Terminal 1 (E)
Auxiliary bottega negative (-) → Terminal 2 (B)Daytime running light LH comes on If the result is not specified, replace the daytime running light assembly LH.
- Apply auxiliary battery voltage to the daytime running light assembly LH and check that the light comes on.
- INSPECT DAYTIME RUNNING LIGHT ASSEMBLY RH
- Apply auxiliary battery voltage to the daytime running light assembly RH and check that the light comes on.
*a Component without harness connected
(Daytime Running Light Assembly RH)OK
Condition Specified Condition Auxiliary bottega positive (+) → Terminal 1 (E)
Auxiliary bottega negative (-) → Terminal 2 (B)Daytime running light RH comes on If the result is not specified, replace the daytime running light assembly RH.
- Apply auxiliary battery voltage to the daytime running light assembly RH and check that the light comes on.