DTC U0233: Lost Communication with Blind Spot Monitor Master Module [02/2014 - 11/2016]: Procedure
- RECONFIRM DTC OUTPUT
Body Electrical > PM1 Gateway > Trouble Codes
- Reconfirm DTCs.
HINT:
If DTC U1002 is output from PM1 Gateway of the power management control ECU, this indicates a sub bus 11 malfunction. Troubleshoot for DTC U1002 and check for malfunctions in sub bus 11.
Result
Result Proceed to U1002 is not output from power management control ECU (Techstream display: PM1 Gateway) A U1002 is output from power management control ECU (Techstream display: PM1 Gateway) B
Result:
B
GO TO DIAGNOSIS PROCEDURE INDICATED BY OUTPUT DTC. Refer to DTC U1002: Lost Communication with Gateway Module (Power Management1) [02/2014 - 11/2016]
Result:
A
See step 2
- Reconfirm DTCs.
- CHECK FOR OPEN IN SUB BUS 11 LINES (BLIND SPOT MONITOR SENSOR LH BRANCH LINE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the M31 blind spot monitor sensor LH connector.
- Measure the resistance according to the value(s) in the table below.
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Standard Resistance
Tester Connection Condition Specified Condition M31-2 (CA1P) - M31-7 (CA1N) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINE OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH)
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Standard Resistance
Tester Connection Condition Specified Condition M31-10 (BLGD) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω - Reconnect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Standard Voltage
Tester Connection Condition Specified Condition M31-5 (BLB) - Body ground Power switch on (IG) 11 to 14 V
Result:
OK
REPLACE BLIND SPOT MONITOR SENSOR LH. Refer to REMOVAL [02/2014 - 11/2016]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.