Inspection [08/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT THERMOSTAT
HINT:
The valve opening temperature is inscribed on the thermostat.
- Immerse the thermostat in water and then gradually heat the water.
- Check that the valve of the thermostat opens at the specified temperature.
Standard Valve Opening Temperature
78 to 82°C (172 to 180°F)
If the valve does not open as specified, replace the thermostat.
- Check the valve lift.
Standard Valve Lift
Item Condition Specified Condition Type A 93°C (199°F) 10 mm (0.394 in.) or more Type B 95°C (203°F) 10 mm (0.394 in.) to 14 mm (0.551 in.) *A for Type A *B for Type B *a Valve Lift If the valve lift is not as specified, replace the thermostat.
- Check that the valve is fully closed when the thermostat is at low temperatures (below 75°C (167°F)).
If not fully closed, replace the thermostat.