LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2016 >> Avalon XLE Plus >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission [U660E] - Diagnostic Codes & Circuit Tests - (Except Hybrid) (2 Of 2) >> Automatic Transaxle System >> DTC P0711: Transmission Fluid Temperature Sensor "A" Performance [10/2015 - 10/2016] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

CONDITION A, B, C AND D:

TFT Less than 20°C (68°F) (THO = -10°C (14°F) at engine start) (Conditions vary with THO at engine)
CONDITION E:

TFT 110°C (230°F) or more