Home >> Toyota >> 2016 >> 4Runner Limited, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Automatic Transmission System (A750E) - Diagnostic Codes & Circuit Tests) >> Automatic Transmission System >> DTC P0748: Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) [08/2015 - 08/2019] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different variant/trim than selected.
ALL

The monitor will run whenever the following DTCs are not stored None
Battery voltage 8 V or higher
Ignition switch ON
Starter OFF
CONDITION (A)

Solenoid current cut status Not cut
Battery voltage 11 V or higher
Target duty cycle 19% or more
CONDITION (B)

Target duty cycle 100%